Table 1. Implement Code (2200-00 TO 2954-14) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2212-13 Auxiliary Valve #1
3. Using MSD (WP 0006), select
2212-13 Code Active - Repeat
Implement 120M and verify 2212- troubleshooting code from the
bration - Continued
13 is active.
beginning.
2212-13 Code Not Active -
Troubleshooting complete.
System Response:
2252-02 Machine Articula-
tion Angle Sensor #2 Data
ECM will log a diagnostic code.
Erratic, Intermittent or Incor-
rect
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2252-02
is Active.
1. Connect MSD (WP 0006), select
0041-03 or 0041-04 Code Active -
Trans/chassis 120M and verify
Diagnose 0041-03 or 0041-04 (WP
0041-03 or 0041-04 are active.
0026) for the Implement ECM first.
0041-03 or 0041-04 Code Not Active
- Proceed to step 2.
2252-02 Code Active - Proceed to
2. Using MSD (WP 0006), verify
Test Step 2.
2252-02 is active for the Trans-
mission ECM or the Implement 1
2252-02 Code Not Active -
ECM.
Troubleshooting complete.
Test Step 2. Inspect Sensor and
Linkage.
1. Inspect articulation angle position
sensor 2 (right) (WP 0009, Figure
123) and linkage for the following:
a. Linkage securely connected
Linkage Loose or Sensor Not
to machine and to sensor.
Secure - Perform installation and
adjustment procedures for articulation
angle position sensor 2 (right) (WP
0257).
Proceed to step 2.
0031-122