TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2174-13 Wheel Lean Right
System Response:
ECM will log diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2174-13 Code Active - Proceed to
implement 120M and verify 2174-
Test Step 2.
13 is active.
2174-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2174-03, 2174 05, or 2174-06 Code
2174-03, 2174-05, or 2174-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2174-13 Code Only Active - Proceed
to step 2.
2. Calibrate wheel Lean right sole-
Wheel Lean Right Solenoid Cannot
noid, refer to Any Implement
Be Calibrated - Replace wheel lean
Moves with Joystick in Hold Posi-
Proceed to step 3.
Wheel Lean Right Solenoid
Calibrated - Proceed to step 3.
3. Using MSD (WP 0006), select
2174-13 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2174-13 is active.
beginning.
2174-13 Code Not Active -
Troubleshooting complete.
0030-48