Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  891    892    893    894    895  896  897    898    899    900    901  
img
TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2181-05 Blade Pitch Forward  2. Using a digital multimeter, mea-
Resistance Less Than 5.0 Ohms -
Solenoid Current Below Nor-
sure for continuity between front
Replace cab lower wiring harness
mal - Continued
attachment wiring harness con-
(WP 0266).
nector U-C1 (WP 0009, Figure
Remove jumper wire between front
121) terminal 16 and terminal 40.
attachment wiring harness connector
Resistance should be less than
U-C41 (WP 0009, Figure 232)
5.0 ohms.
terminal 1 and terminal 2.
Connect front attachment wiring
harness connector U-C41 (WP 0009,
Figure 232) to blade pitch forward
solenoid (WP 0009, Figure 233) (WP
0180).
Proceed to step 3.
Resistance 5.0 Ohms or Greater -
Replace front attachment wiring
harness (WP 0180).
Connect cab lower wiring harness
connector P-C41 (WP 0009, Figure
68) to implement 1 ECM J1 (WP
0009, Figure 69) (WP 0268).
Proceed to step 3.
3. Using MSD (WP 0006), select
2181-05 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2181-05 is not active.
beginning.
2181-05 Code Not Active -
Troubleshooting complete.
2181-06 Blade Pitch Forward
System Response:
Solenoid Current Above
ECM will log diagnostic code.
Normal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2181-06 Code Active - Proceed to
implement 120M and verify 2181-
Test Step 2.
06 is active.
2181-06 Code Not Active -
Troubleshooting complete.
0030-53