TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2166-06 Blade Sideshift
6. Using MSD (WP 0006), select
2166-06 Code Active - Repeat
Right Solenoid Current
Implement 120M and verify 2166- troubleshooting code from the
Above Normal - Continued
06 is active.
beginning.
2166-06 Code Not Active -
Troubleshooting complete.
System Response:
2166-13 Blade Sideshift
ECM will log a diagnostic code.
bration
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2166-13
is Active.
1. Connect MSD (WP 0006). Select 2166-13 Code Active - Proceed to
Implement 120M and verify 2166- Test Step 2.
13 is active.
2166-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2166-03, 2166 05, or 2166-06 Code
2166-03, 2166-05, or 2166-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2166-13 Code Only Active - Proceed
to step 2.
2. Calibrate blade sideshift right
Blade Sideshift Right Solenoid
Cannot Be Calibrated - Replace
Moves with Joystick in Hold Posi-
blade sideshift right solenoid (WP
0245).
Proceed to step 3.
Blade Sideshift Right Solenoid
Calibrated - Proceed to step 3.
0029-49