TM 5-3805-293-23-2
0029
Table 1. Implement Code (2160-03 TO 2168-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2160-13 Blade Left Raise
System Response:
ECM will log a diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2160-13
is Active.
1. Connect MSD (WP 0006). Select 2160-13 Code Active - Proceed to
Implement 120M and verify 2160- Test Step 2.
13 is active.
2160-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006), verify
2160-03, 2160 05, or 2160-06 Code
Active - Troubleshoot other
2160-03, 2160-05, or 2160-06 are
diagnostic codes first in this work
not active.
package.
2160-13 Code Only Active - Proceed
to step 2.
Blade Left Raise Solenoid Cannot
2. Calibrate blade left raise solenoid,
Be Calibrated - Replace blade left
refer to any Implement Moves
with Joystick in Hold Position (WP
Proceed to step 3.
Blade Left Raise Solenoid
Calibrated - Proceed to step 3.
2160-13 Code Active - Repeat
3. Using MSD (WP 0006), select
Implement 120M and verify 2160- troubleshooting code from the
beginning.
13 is active.
2160-13 Code Not Active -
Troubleshooting complete.