Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  760    761    762    763    764  765  766    767    768    769    770  
img
TM 5-3805-293-23-2
0028
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2155-04 Circle Drive Lever
System Response:
Position Sensor Voltage
ECM will log diagnostic code.
Below Normal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using the MSD (WP 0006). Select  2155-04 Code Active - Proceed to
Implement 120M and verify 2155- Test Step 2.
04 is active.
2155-04 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Signal Voltage to
Sensor.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect cab lower wiring har-
ness connector PE-C8 (WP 0009,
Figure 50) from RH joystick con-
nector J1 (WP 0283).
3. Turn ignition switch and battery
disconnect switch to the ON posi-
tion.
4. Using digital multimeter, test for
Voltage Between 13.5 to 14.5 Volts -
voltage between harness connec-
Replace RH joystick (WP 0283).
tor connector PE-C8 (WP 0009,
Proceed to step 5.
Figure 50) terminal 9 and terminal
Voltage Out of Specifications of
3. Voltage should be between
13.5 to 14.5 Volts - Proceed to Test
13.5 to 14.5 volts.
Step 3.
2155-04 Code Active - Repeat
5. Using MSD (WP 0006), select
troubleshooting code from the
Implement 120M ECM and verify
beginning.
2155-04 is not active.
2155-04 Code Not Active -
Troubleshooting complete.
0028-72