• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  763    764    765    766    767  768  769    770    771    772    773  
img
TM 5-3805-293-23-2
0028
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2155-08 Circle Drive Lever
5. Using MSD (WP 0006), select
2155-08 Code Active - Repeat
Position Sensor Abnormal
Implement 120M ECM and verify
troubleshooting code from the
Frequency, Pulse Width or
2155-08 is not active.
beginning.
Period - Continued
2155-08 Code Not Active -
Troubleshooting complete.
Test Step 3. Test for Open Cab
Lower Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect the cab lower wiring
harness connector P-C41 (WP
0009, Figure 68) from implement
ECM J1 (WP 0009, Figure 69)
(WP 0266).
3. Disconnect the cab lower wiring
harness connector P-C39 (WP
0009, Figure 70) from implement
ECM J2 (WP 0009, Figure 71)
(WP 0266).
4. Connect jumper wire between cab
lower wiring harness connector
PE-C8 (WP 0009, Figure 50) ter-
minal 9 and terminal 3.
5. Using digital multimeter, measure
Resistance Less Than 5.0 Ohms -
for continuity between cab lower
Replace implement 1 ECM (WP
wiring harness connector P-C39
0268).
(WP 0009, Figure 70) terminal 32
Remove jumper wire between cab
and P-C41 (WP 0009, Figure 68)
lower wiring harness connector PE-
terminal 70.
C8 (WP 0009, Figure 50) terminal 9
Resistance should be less than
and terminal 3.
5.0 ohms.
Connect cab lower wiring harness
connector PE-C8 (WP 0009, Figure
50) to RH joystick connector J1 (WP
0283).
Proceed to step 6.
Resistance 5.0 Ohms or Greater -
Replace cab lower wiring harness
(WP 0266).
Proceed to step 6.
6. Using MSD (WP 0006), select
2155-08 Code Active - Repeat
Implement 120M ECM and verify
troubleshooting code from the
2155-08 is not active.
beginning.
2155-08 Code Not Active -
Troubleshooting complete.
0028-75