TM 5-3805-293-23-2
0028
Table 1. Implement Code (2146-02 to 2156-08) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2150-04 Blade Left Lift Lever
Test Step 3. Test for Shorted Cab
Position Sensor Voltage
Lower Wiring Harness.
Below Normal - Continued
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect the cab lower wiring
harness connector P-C39 (WP
0009, Figure 70) from implement
ECM J2 (WP 0009, Figure 71)
(WP 0266).
for continuity between cab lower
harness (WP 0266).
wiring harness connector P-C39
Proceed to step 4.
(WP 0009, Figure 70) terminal 49
and machine ground. There
ECM (WP 0268).
should be no continuity.
Connect cab lower wiring harness
connector P-C51 (WP 0009, Figure
118) to LH joystick connector J1 (WP
0282).
Proceed to step 4.
4. Using MSD (WP 0006), select
2150-04 Code Active - Repeat
Implement 120M ECM and verify
troubleshooting code from the
2150-04 is not active.
beginning.
2150-04 Code Not Active -
Troubleshooting complete.
2150-08 Blade Left Lift Lever
System Response:
Position Sensor Abnormal
ECM will log diagnostic code.
N OT E
Period
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
0028-27