TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0597-03 Main Hydraulic
3. Using the MSD (WP 0006), select 0597-03 Code Active - Repeat
Pump Discharge Pressure
Implement 120M and verify 0597- troubleshooting code from the
Sensor Voltage Above
03 is not active.
beginning.
Normal - Continued
0597-03 Code Not Active -
Troubleshooting complete.
0597-04 Main Hydraulic
System Response:
Pump Discharge Pressure
ECM will log a diagnostic code.
Sensor Voltage Below Nor-
N OT E
mal
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 0597-04
is Active.
1. Connect MSD (WP 0006). Select 0597-04 Code Active - Proceed to
Implement 120M and verify 0597- Test Step 2.
04 is active.
0597-04 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Hydraulic Pump
Discharge Pressure Sensor Circuit.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect the hydraulic valve
wiring harness connector AP-C2
(WP 0009, Figure 214) from
hydraulic pump discharge pres-
sure sensor.
3. Turn ignition switch and battery
disconnect switch to the ON posi-
tion.
4. Using MSD (WP 0006), select
0597-04 Code Remains Active -
Implement 120M and check if
Proceed to Test Step 3.
0597-03 becomes active.
0597-03 Code Becomes Active -
Replace hydraulic pump discharge
pressure sensor (WP 0227).
Proceed to step 5.
0026-78