Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0597-03 Main Hydraulic
Pump Discharge Pressure
No Continuity - Replace cab lower
Sensor Voltage Above
sis wiring harness connector FA-
wiring harness (WP 0266).
Normal - Continued
C22 (WP 0009, Figure 47) termi-
Connect the hydraulic valve wiring
nal 23 and all other FA-C22 termi-
harness connector AP-C2 (WP 0009,
nals.
Figure 214) to hydraulic pump
There should be no continuity.
discharge pressure sensor.
Proceed to step 3.
3. Using the MSD (WP 0006), select 0597-03 Code Active - Repeat
Implement 120M and verify 0597- troubleshooting code from the
03 is not active.
beginning.
0597-03 Code Not Active -
Troubleshooting complete.
Test Step 11. Test for Shorted
Hydraulic Valve Wiring Harness.
1. Disconnect the hydraulic valve
wiring harness connector AP-C1
(WP 0009, Figure 213) from rear
chassis wiring harness connector
FA-C30 (WP 0009, Figure 211).
wiring harness (WP 0190).
valve wiring harness connector
Connect the rear chassis wiring
AP-C1 (WP 0009, Figure 213) ter-
harness connector FA-C22 (WP 0009,
minal 3 and all other AP-C1 termi-
Figure 47) to cab lower wiring harness
nals.
connector P-C69 (WP 0009, Figure
There should be no continuity.
46) (WP 0188).
Connect the cab lower wiring harness
connector P-C41 (WP 0009, Figure
68) to implement ECM J1 (WP 0009,
Figure 69) (WP 0268).
Proceed to step 3.
wiring harness (WP 0188).
Connect the hydraulic valve wiring
harness connector AP-C2 (WP 0009,
Figure 214) to hydraulic pump
discharge pressure sensor.
Connect the cab lower wiring harness
connector P-C41 (WP 0009, Figure
68) to implement ECM J1 (WP 0009,
Figure 69) (WP 0268).
Proceed to step 3.
0026-77