TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0597-03 Main Hydraulic
Test Step 8. Test for Open Hydrau-
Pump Discharge Pressure
lic Valve Wiring Harness.
Sensor Voltage Above
1. Disconnect the hydraulic valve
Normal - Continued
wiring harness connector AP-C1
(WP 0009, Figure 213) from rear
chassis wiring harness connector
FA-C30 (WP 0009, Figure 211).
Replace rear chassis wiring harness
valve wiring harness connector
(WP 0188).
AP-C1 (WP 0009, Figure 213) ter-
Remove jumper wire between
minal 2 and terminal 3.
hydraulic valve wiring harness
Resistance should be 5.0 ohms or
connector AP-C2 (WP 0009, Figure
less.
214) terminal A and terminal B.
Connect the hydraulic valve wiring
harness connector AP-C2 (WP 0009,
Figure 214) to hydraulic pump
discharge pressure sensor.
Connect the cab lower wiring harness
connector P-C41 (WP 0009, Figure
68) to implement ECM J1 (WP 0009,
Figure 69) (WP 0268).
Proceed to step 3.
Replace hydraulic valve wiring
harness (WP 0190).
Connect the rear chassis wiring
harness connector FA-C22 (WP 0009,
Figure 47) to cab lower wiring harness
connector P-C69 (WP 0009, Figure
46) (WP 0188).
Connect the cab lower wiring harness
connector P-C41 (WP 0009, Figure
68) to implement ECM J1 (WP 0009,
Figure 69) (WP 0268).
Proceed to step 3.
3. Using the MSD (WP 0006), select 0597-03 Code Active - Repeat
Implement 120M and verify 0597- troubleshooting code from the
03 is not active.
beginning.
0597-03 Code Not Active -
Troubleshooting complete.
0026-75