Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  479    480    481    482    483  484  485    486    487    488    489  
img
TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0168-02 Electrical System
System Response:
Voltage Data Erratic, Inter-
ECM will log a diagnostic code and a
mittent, or Incorrect
warning will appear on the instrument
panel.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is Active.
Test Step 1. Verify if Code 0168-02
is Active in Implement ECM.
1. Connect MSD (WP 0006). Select  0168-02 Code Is Active - Proceed to
Implement 120M and verify 0168- Test 2.
02 is active.
0168-02 Code Not Active -
Troubleshooting complete.
Test Step 2. Test Battery (+) Supply
Circuits.
1. Turn ignition switch and battery
disconnect switch to the OFF
position (TM 5-3805-293-10).
2. Disconnect harness connector
FA-C20 (WP 0009, Figure 113)
from transmission ECM J1 (WP
0009, Figure 112) (WP 0137).
3. Turn battery disconnect and igni-
tion switch to the ON position (TM
5-3805-293-10).
4. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 31 and machine ground.
Proceed to step 10.
Voltage should be between 18 to 26
Voltage OK - Proceed to step 5.
volts.
0026-23