Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  468    469    470    471    472  473  474    475    476    477    478  
img
TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0168-00 Electrical System
4. Using digital multimeter, test for
Voltage Less Than 18 Volts -
Voltage High - Continued
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 31 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 5.
5. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 38 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 6.
6. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 39 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 7.
7. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 46 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 8.
8. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 47 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to Test Step 3.
9. Using the MSD (WP 0006), select  0168-00 Code Remains Active -
Implement 120M and verify 0168- Repeat troubleshooting code from the
00 is not active.
beginning.
0168-00 Code Not Active -
Troubleshooting complete.
0026-12