TM 5-3805-293-23-2
0020
Table 1. Transmission Code (2113-03 TO 2304-06) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2252-02 Machine Articula-
System Response:
tion Angle Sensor #2 Data
ECM will log a diagnostic code.
Erratic, Intermittent or Incor-
rect
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Verify if Code 2252-02
is Active.
1. Connect MSD (WP 0006), select
0041-03 or 0041-04 Code Active -
Trans/chassis 120M and verify
Diagnose 0041-03 or 0041-04 (WP
0041-03 or 0041-04 are active.
0025 01) for the Implement ECM first.
0041-03 or 0041-04 Code Not Active
- Proceed to step 2.
2. Using MSD (WP 0006), verify
2252-02 Code Active - Proceed to
2252-02 is active for the transmis-
Test Step 2.
sion ECM or the Implement 1
2252-02 Code Not Active - Trouble-
ECM.
shooting complete.
Test Step 2. Inspect Sensor and
Linkage.
1. Inspect articulation angle position
sensor 2 (right) (WP 0009, Figure
123) and linkage for the following:
a. Linkage securely connected
Linkage Loose or Sensor Not
to machine and to sensor.
Secure - Perform installation and
adjustment procedures for articula-
tion angle position sensor 2 (right)
(WP 0257).
Proceed to step 2.
b. Remove articulation angle
Sensor Damaged - Replace articula-
position sensor 2 (right) and
tion angle position sensor 2 (right)
visually inspect sensor hous-
(WP 0257).
ing, and harness connector
Proceed to step 2.
for damage (WP 0257).
0020-116