• Home
  • Download PDF
  • Order CD-ROM
  • Order in Print
Table 1. Transmission Code (1471-02 to 1961-04) Troubleshooting Procedures - Continued.
Table 1. Transmission Code (1471-02 to 1961-04) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  1189    1190    1191    1192    1193  1194  1195    1196  
img
. . . . . . . .
TM 5-3805-293-23-1
0019
Table 1. Transmission Code (1471-02 to 1961-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1961-03 Accumulator Pres-
4. Using the MSD (WP 0006), select
1961-03 Code Active - Repeat trou-
sure Sensor Voltage Above
Trans/chassis 120M and verify
bleshooting code from the beginning.
Normal - Continued
1961-03 is not active.
1961-03 Code Not Active - Trouble-
shooting complete.
1961-04 Accumulator Pres-
System Response:
sure Sensor Voltage Above
ECM will log a diagnostic code and a
Normal
warning will appear on the messenger
while the diagnostic code is Active.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is Active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is Active.
Test Step 1. Test Signal Voltage.
1. Connect MSD (WP 0006). Select
Trans/chassis 120M and verify
1961-04 is active.
2. Turn ignition switch and battery
disconnect switch to the OFF
position.
3. Disconnect the starter harness
connector FG-C2 (WP 0009, Fig-
ure 137) from service brake accu-
mulator pressure sensor (WP
0009, Figure 138).
4. Turn ignition switch and battery
disconnect switch to the ON posi-
tion.
5. Using digital multimeter, measure
Voltage OK (9.7 - 10.3 Volts) -
voltage between starter harness
Replace accumulator pressure sensor
connector FG-C2 (WP 0009, Fig-
(WP 0233).
ure 137) terminal C and terminal
Proceed to step 6.
B (ground). Voltage should be 9.7
Voltage Not OK - Proceed to Test
- 10.3 Volts.
Step 2.
6. Using the MSD (WP 0006), select
1961-04 Code Active - Repeat trou-
Trans/chassis 120M and verify
bleshooting code from the beginning.
1961-04 is not active.
1961-04 Code Not Active - Trouble-
shooting complete.
0019-104