TM 5-3805-293-23-1
0008
RECORDING DIAGNOSTIC CODES AND COPYING CONFIGURATION FROM ECM CONTINUED
b. ECM Select window (Figure 3, Item 1) will display. Highlight the ECM to be programmed (Figure 3, Item 2),
and select the OK button (Figure 3, Item 3). The configuration window will display, ensure all check boxes
are selected on left side of display (Figure 3, Item 8) and select Save to File button (Figure 3, Item 5) and
select location for files to be saved.
c.
The ECM Replacement pop window (Figure 3, Item 7) will display, select the OK button (Figure 3, Item 6).
N OT E
By default, file is saved in Downloads\ECM Replacement folder. Note the file name engine
serial number, date, and time of download.
Figure 3. ECM Select Window.
08
0008-4