DETECTING AN ELECTRONIC CONTROL MODULE (ECM) USING ELECTRONIC TECHNICIAN (ET)
Figure 2. Diagnostic Connector.

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  64    65    66    67    68  69  70    71    72    73    74  
img
.
TM 5-3805-293-23-1
0007
SOFTWARE INSTALLATION AND CONNECTING MSD
N OT E
First-time users should revew Maintenance Support Device (MSD) operator's training
i
installed on MSD.
If this is the first use of the ET, perform steps 1 through 3.
1. Install communication adapter driver software (Figure 1, Item 5) on MSD (Figure 1, Item 1).
2. Install ET software (Figure 1, Item 3) on MSD (Figure 1, Item 1).
3. Review tutorial on ET CD.
4. Connect cable (Figure 1, Item 9) to "COMPUTER" end of communication adapter (Figure 1, Item 2) and to
USB port (Figure 1, Item 11) of MSD (Figure 1, Item 1).
5. If power supply is available, connect power supply cable (Figure 1, Item 8) to power supply port (Figure 1,
Item 10) on MSD (Figure 1, Item 1).
6. If power supply is available, connect power supply cable (Figure 1, Item 7) to power supply (Figure 1, Item 6)
and power source.