TM 5-3805-261-34HYDRAULIC SYSTEM MAINTENANCE. (cont)10-11.HydraulicPumpReliefValve. (Sheet 3 of 4)DISASSEMBLY (cont)8.Remove preformed packing (12)from plug (13, Figure 10-103).Discard preformed packing (12).WARNINGCOMPRESSED SPRINGSAlways wear safety glasseswhen removing or installingparts restraining compressedsprings. Remove restrainingparts slowly to relievespring pressure. INJURY mayresult if you do not followthis procedure. If you areinjured while removing orinstalling compressedsprings, obtain medical aidimmediately.9.Remove retainer (14) and spring(15) from valve (16, Figure10-104).CLEANINGClean all parts. Refer to Chapter 2.INSPECTIONInspect all parts. Refer to Chapter2.ASSEMBLY1Install spring (15) and retainer(14) on valve (16, Figure10-104).2.Install new preformed packing12) on plug (13, Figure 10-103).Figure 10-103.Figure 10-104.Go to Sheet 410-70