TM 5-3805-261-34
HYDRAULIC SYSTEM MAINTENANCE. (cont)
10-6.
Blade Float Pilot Valve. (Sheet 2 of 2)
DISASSEMBLY
1.
Remove nut (1), coil (2), cart-
ridge (3) and seals (4, 5 and 6)
from body (14, Figure 10-65).
Discard seals (4, 5 and 6).
2.
Remove screw (7), washer (8),
coil (9), cartridge (10) and
seals (11, 12 and 13, Figure
10-66). Discard seals (11, 12
and 13).
CLEANING
Clean all parts. Refer to Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter 2.
ASSEMBLY
1.
Install new seals (13, 12 and
11), cartridge (10), coil (9),
washer (8) and screw (7) in body
(14, Figure 10-66).
2.
Install new seals (6, 5 and 4),
cartridge (3), coil (2) and nut
(1, Figure 10-65).
NOTE
Return 130G Grader to
original equipment condition.
End of Task
Figure 10-65.
Figure 10-66.
10-44