TM 5-3805-261-34HYDRAULIC SYSTEM MAINTENANCE. (cont)10-7.BladeFloatCheckValve. (Sheet 2 of 4)DISASSEMBLY1.Loosen plug (1) carefully torelieve spring (3, Figure 10-67)tension. Remove plug (1),preformed packing (2), spring (3)and ball (4). Discard preformedpacking (2).2.Loosen plug (7) carefully torelieve spring (9) tension.Remove plug (7), preformed packing(8), spring (9) and ball (10).Discard preformed packing (8).3.Remove plug (13) and preformedpacking (14, Figure 10-68). Dis-card preformed packing (14).4.Remove plug (15) and preformedpacking (16). Discard preformedpacking (16).5.Remove plug (17) and preformedpacking (18). Discard preformedpacking (18).6.Remove plug (21) and preformedpacking (22). Discard preformedpacking (22).7.Remove plug (19) and preformedpacking (20). Discard preformedpacking (20).Brass rod and hammer must beused to remove seat and pistonto prevent damage.8.Using a .25 inch diameter brassrod and hammer, remove seat (5)and piston (6) from body (23).9.Using a .69 inch diameter brassrod and hammer, remove seat (11)piston (12) from body (23).Go to Sheet 3CAUTIONFigure 10-67.Figure 10-68.10-46