TM 5-3805-261-23-2
ELECTRONIC MONITORING SYSTEM (EMS) MAIN
WIRING HARNESS REPLACEMENT - CONTINUED
0291 00
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP 0021 00.
INSTALLATION
CAUTION
Do not position electrical monitor wiring harness against any rough surface. Failure to follow this procedure
could cause chafing.
NOTE
Route electrical monitor wiring harness exactly as it was removed.
1.
Position EMS wiring harness (1) on machine.
2.
Connect electrical monitor wiring harness (1) to jumper wire (17), alternator (16) (WP 0062 00), starting motor (15)
(WP 0067 00), fuel pressure switch (14) (WP 0115 00), hydraulic oil temperature switch (4) (WP 0116 00), hourmeter
switch (3) (WP 0113 00), engine oil pressure switch (2) (WP 0113 00), coolant temperature switch (5) (WP 0114 00),
warning horn (6) (WP 0119 00), fuse box (13) (WP 0096 00), air pressure switches (12) (WP 0112 00), supplemental
steering (10) (WP 0086 00), EMS panel (7) (WP 0069 00), lamp (9) (WP 0071 00), and test switch (8) (WP 0070 00).
3.
Install new tie straps and clips/clamps (11).
4.
Install steering control console plates (WP 0197 00 or WP 0198 00).
5.
Install left and right side engine panels (WP 0182 00).
6.
Connect battery cables (WP 0125 00).
END OF WORK PACKAGE
0291 00-3/(-4 Blank)