TM 5-3805-261-23-1
HYDRAULIC PUMP AND CONTROL VALVE LINES AND FITTINGS REPLACEMENT - CONTINUED
0249 00
INSTALLATION - CONTINUED
46
11.
Install new preformed packing (47) and connector (46)
44
47
48
45
to right hydraulic control valve (49).
33
12.
Position hose assembly (44) to machine. Install new
preformed packing (45) and connect hose assembly to
connector (46).
13.
Install new preformed packing (48) and connector
(54).
14.
Position hose assembly (33) to machine. Install new
preformed packing (55) and connect hose assembly to
connector (54).
49
15.
Install new preformed packing (50) and elbow (51).
16.
Install new preformed packing (52) and connect hose
assembly (53) to elbow (51).
55
53
51 50
54
52
397-1639
17.
Install hose clamp (37) to support (34) with bolt (38), washer (36), and nut (35).
18.
Install new preformed packing (40) and install tee (31) to connector (41).
19.
Install new preformed packing (32) and connect hose assembly (33) to end of tee (31).
20.
Position hose assembly (9) to machine. Install new preformed packing (39) and connect hose assembly to middle of tee
(31).
21.
Install new preformed packing (28) and elbow (29).
22.
Position hose assembly (27) to machine. Install new preformed packing (30) and connect hose assembly to elbow (29).
30 27 31
32
28 29
33
34
35
36
43
37
42
38
41
40
397-1633
0249 00-10