TM 5-3805-261-23-1
DISCONNECT SWITCH CABLE REPLACEMENT - CONTINUED
0142 00
INSTALLATION
1.
Connect cable (3) and install washer (21) and nut (22) on disconnect switch (23) inside operator panel console.
2.
For Type I machine, disregard steps 3 through 14 and step 16, perform steps 15 and 17 only.
3.
Install clip (17) on cable (3) inside operator panel console.
4.
Install washer (16), bolt (15), and clip (17) to frame.
5.
Install two clips (20) on cable (3) under right side of operator compartment.
6.
Install two washers (19), bolts (18), and clips (20) to frame.
23
21
22
3
20
19
18
17
16
15
23
3
397-424
0142 00-4