TM 5-3805-261-23-1
FAN LUBRICATION LINE REPLACEMENT - CONTINUED
0062 00
REMOVAL
CAUTION
1.
Disconnect hose assembly (5) from adapter (7).
2.
Remove fitting (1) and adapter (7).
3.
Remove bolt (3), washer (2), and clamp (6).
4.
Remove hose assembly (5) from fan bracket (4).
4
2
3
1
7
5
6
5
397-187
CLEANING AND INSPECTION
Clean and inspect all parts in accordance with WP 0020 00.
INSTALLATION
1.
Connect hose assembly (5) to fan bracket (4).
2.
Install clamp (6), washer (2), and bolt (3).
3.
Install adapter (7) and fitting (1).
4.
Install hose assembly (5) to adapter (7).
5.
6.
END OF WORK PACKAGE
0062 00-2