TM 5-3805-261-23-1
PREVENTIVE MAINTENANCE CHECKS
AND SERVICES (PMCS) PROCEDURES - CONTINUED
0023 00
LOCATION
ITEM TO
ITEM
MAN-
NOT FULLY MISSION
CHECK/
NO.
INTERVAL
HOURS
PROCEDURE
CAPABLE IF:
SERVICE
Drain and refill circle drive housing.
29
2000 Hours 0.5
Circle Drive
or Annually
Housing
a. Position approved container under
drain plug (1) and remove plug.
b. Allow oil to drain and install plug
(1).
c. Remove plug (2) and fill circle
drive housing with lubricating oil
bottom of well. Install plug (2).
2
1
397-1094
END OF WORK PACKAGE
0023 00-9