TM 5-3805-261-23-1
PREVENTIVE MAINTENANCE CHECKS
AND SERVICES (PMCS) PROCEDURES - CONTINUED
0023 00
LOCATION
ITEM TO
ITEM
MAN-
CHECK/
NOT FULLY MISSION
NO.
INTERVAL
HOURS
SERVICE
PROCEDURE
CAPABLE IF:
Replace desiccant in air dryer (WP
5
250 Hours
Air Dryer (If
or Semi-
Equipped)
Annually
6
500 Hours
or Semi-
Breather
Annually
WARNING
1.0
Hydraulic
7
500 Hours
System
or Semi-
Hot oil can cause burns. The hydraulic tank is hot and under
Annually
pressure when at operating temperature. Remove the fill cap
ONLY when the engine is stopped and the cap is cool
enough to touch with your hand. Remove the fill cap slowly
to relieve pressure.
a. Inspect tank for leaks, broken fit-
tings, cracked welds, or missing
parts. Repair or replace as neces-
sary (WP 0339 00).
c. Change hydraulic tank filters (WP
Change filter and clean strainer. (WP
0.5
Transmis-
8
500 Hours
or Semi-
sion/Differ-
Annually
ential
Housing
9
500 Hours
or Semi-
Annually
WARNING
Do NOT perform fuel system checks, inspections or mainte-
nance while smoking or near fire, flames or sparks. Fuel may
ignite, causing damage to machine and injury or death.
Operating personnel must wear fuel-resistant gloves and eye
protection when handling fuels. If exposed to fuel, promptly
wash exposed skin and change fuel-soaked clothing.
a. Disassemble, clean and inspect fuel
b. Clean and inspect fill tube screen
c. Disassemble, clean and inspect pri-
0023 00-2