STARTING SYSTEM STE/ICE-R TESTING - CONTINUED
0017 00
TEST 89 - 0-45 VOLTS - CONTINUED
(4)
Perform test using procedure TEST 89 as instructed in TM 9-4910-571-12&P.
(5)
Voltage drop should be no more than 1.0 volt.
(6)
Return machine to its original condition.
b.
Starter Ground to Frame.
(1)
Refer to VTM General Setup and Checkout Instructions in TM 9-4910-571-12&P. Connect power cable to
battery.
(2)
Attach red lead clip to starter. Ground black lead clip to frame. Make sure that all electrical contacts are
clean.
STARTER
397-218
(3)
Perform test using procedures TEST 89 as instructed in TM 9-4910-571-12&P.
(4)
Voltage drop should be no more than 0.2 volt.
(5)
Return machine to its original condition.
END OF WORK PACKAGE