TM 5-3805-261-23-1
STARTING SYSTEM STE/ICE-R TESTING - CONTINUED
0017 00
TEST 89 - STARTER NEGATIVE CABLE VOLTAGE DROP
1.
Refer to VTM General Setup and Checkout Instructions in TM 9-4910-571-12&P. Connect power cable to battery.
POWER
POWER
CABLE
CABLE
BATTERY
BATTERY
+
-
397-081
RIGHT-SIDE BATTERY
LEFT-SIDE BATTERY
2.
Attach red lead clip to ground terminal F. Attach black lead clip to battery negative terminal. Make sure that electrical
contacts are clean.
3.
Perform test using procedure TEST 89 as instructed in TM 9-4910-571-12&P.
4.
Voltage drop should not be more than 0.1 volt.
5.
Return machine to its original condition.
TEST 89 - STARTER SOLENOID VOLTAGE
1.
Refer to VTM General Setup and Checkout Instructions in TM 9-4910-571-12&P. Connect power cable to battery.
2.
Attach red lead clip to positive terminal C on starter solenoid. Attach black lead clip to battery negative terminal. Make
sure that electrical connections are clean.
3.
Perform test using procedure TEST 89 as instructed in TM 9-4910-571-12&P.
4.
Starter solenoid voltage should be 18 volts.
5.
Return machine to its original condition.
0017 00-3