TM 5-3805-261-23-1
STARTING SYSTEM STE/ICE-R TESTING - CONTINUED
0017 00
TEST 89 - 0-45 VOLTS - CONTINUED
(3)
Perform test using procedures TEST 89 as instructed in TM 9-4910-571-12&P.
(4)
Maximum voltage drop allowable is 0.1 volt.
(5)
Return machine to its original condition.
b.
(1)
Refer to VTM General Setup and Checkout Instructions in TM 9-4910-571-12&P. Connect power cable to
battery.
(2)
Attach black lead clip to terminal C. Attach red lead clip to battery positive terminal. Make sure that all
electrical contacts are clean.
B
C
+
D
A
E
F
RIGHT-SIDE BATTERY
397-217
397-216
(3)
Perform test using procedure TEST 89 as instructed in TM 9-4910-571-12&P.
(4)
Maximum voltage drop allowable is 0.1 volt.
(5)
Return machine to its original condition.
2.
Negative Voltage Drop.
a.
Master Disconnect Switch.
(1)
Refer to VTM General Setup and Checkout Instructions in TM 9-4910-571-12&P. Connect power cable to
battery.
0017 00-6