TM 5-3805-261-23-1
CHARGING SYSTEM STE/ICE-R TESTING - CONTINUED
0016 00
TEST 89 - ALTERNATOR/GENERATOR OUTPUT VOLTAGE - CONTINUED
2.
Attach red lead clip to output terminal of alternator.
Ground black lead clip. Make sure that electrical con-
nections are clean.
INNER
397-205
3.
Perform test using procedure TEST 89 as instructed in TM 9-4910-571-12&P.
4.
Voltage should be 26.5 to 28.0 volts.
5.
Return machine to its original condition.
TEST 90 - ALTERNATOR OUTPUT CURRENT SENSE
1.
Refer to VTM General Setup and Checkout Instructions in TM 9-4910-571-12&P. Connect power cable to battery.
BATTERY
BATTERY
-
+
LEFT-SIDE BATTERY
RIGHT -SIDE BATTERY
397-081
0016 00-2