TM 5-3805-261-20
HORN AND BACK-UP ALARM MAINTENANCE. (cont)
7-101.
Electrical Monitoring System Alarm. (Sheet 2 of 2)
REMOVAL
NOTE
All
wire,
cable
and
harness
assemblies must be tagged before
disconnecting to aid in installation.
1.
Disconnect wiring harness (1, Figure 7-151)
at plug from inner panel in operators
console.
2.
Remove bolt (2) and washer (3).
3.
Remove alarm (4).
CLEANING
Clean all parts. Refer to Chapter 2.
INSPECTION
Inspect all parts. Refer to Chapter 2.
INSTALLATION
1.
Install alarm (4, Figure 7-151).
2.
Install washer (3) and bolt (2).
3.
Connect wiring harness (1) at plug to inner
panel in operators console.
NOTE
Return
130G
Grader
to
original
equipment condition.
Figure 7-151
End of Task
7-246