TM 5-3805-261-20
BLADE TROUBLESHOOTING AND MAINTENANCE PROCEDURES.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
b.
CENTERSHIFT LOCK ASSEMBLY FAILS TO OPERATE.
Step 2. Check for air pressure at the centershift control valve (Figure 17-2).
Figure 17-2
If the centershift control valve is damaged or defective--replace. Refer to paragraph 17-6.
Step 3. Check for air pressure at the centershift lock assembly (Figure 17-3).
Figure 17-3
If the centershift lock assembly is damaged or defective--replace. Refer to paragraph 17-4.
17-3