TM 5-3805-261-10
SECTIONALIZATION FOR AIR TRANSPORT - CONTINUED
0019 00
DISASSEMBLY - CONTINUED
12.
Install the pump driveshaft lock bar on pump yoke using two driveshaft bolts (6). Be sure that free end of lock bar is
pointing toward right hand side of machine. Lock bar will prevent pump rotation.
6
LOCK BAR
397-1100
13.
Remove two bolts (12), washers (13), nuts (15), washers (16), and retainer caps (14) from left articulation cylinder (17).
14
15,16
12,13
17
397-1068
15,16
12,13
14
(HIDDEN)
0019 00-3