TM 5-3805-293-23-4
0264
CHARGE VALVE REMOVAL
000264
WARN I N G
Accumulator is under nitrogen pressure. Ensure that nitrogen pressure is discharged from
accumulator prior to removing valve from accumulator. Refer to procedure in this work
package. Failure to follow this warning may result in injury or death to personnel.
1. Remove accumulator from machine and discharge nitrogen pressure. Refer to procedures in this work
package.
2. Remove charge valve (Figure 4, Item 1) and O-ring (Figure 4, Item 2) from accumulator (Figure 4, Item 3).
Discard O-ring.
Figure 4. Charge Valve.
0264
END OF TASK
CLEANING AND INSPECTION
000264
Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0346).
END OF TASK
CHARGE VALVE INSTALLATION
000264
1. Install new O-ring (Figure 4, Item 2) and charge valve (Figure 4, Item 1) on accumulator (Figure 4, Item 3).
2. Install accumulator (Figure 4, Item 3) on machine. Refer to procedure in this work package.
END OF TASK