TM 5-3805-293-23-4
0240
REMOVAL CONTINUED
N OT E
Tag and mark wires to aid in installation.
2. Remove two screws (Figure 2, Item 1), lockwashers (Figure 2, Item 2), and circuit breaker (Figure 2,
Item 4) from circuit breaker box (Figure 2, Item 3). Discard lockwashers.
3. Remove two screws (Figure 2, Item 6), wire eyelets (Figure 2, Item 7), and lockwashers (Figure 2, Item 5) from
circuit breaker (Figure 2, Item 4). Discard lockwashers.
0240
END OF TASK
CLEANING AND INSPECTION
000240
1. Clean and inspect all mechanical parts IAW Mechanical General Maintenance Instructions (WP 0346).
2. Clean and inspect all electrical parts IAW Electrical General Maintenance Instructions (WP 0347).
END OF TASK
INSTALLATION
000240
N OT E
Install wires as tagged during removal.
1. Install two new lockwashers (Figure 2, Item 5), wire eyelets (Figure 2, Item 7), and screws (Figure 2, Item 6) on
circuit breaker (Figure 2, Item 4).
2. Install circuit breaker (Figure 2, Item 4), two new lockwashers (Figure 2, Item 2), and screws (Figure 2, Item 1)
on circuit breaker box (Figure 2, Item 3).