TM 5-3805-293-23-4
0207
DISASSEMBLY CONTINUED
C AU T I O N
If bulb is to be reused, handle bulb with a clean dry rag. Do not handle bulb with bare
hands. Failure to follow this caution may result in damage to equipment.
2. Release spring clip (Figure 2, Item 6) and remove bulb (Figure 2, Item 3) from lens (Figure 2, Item 1).
3. Disconnect bulb connector (Figure 2, Item 5) from harness (Figure 2, Item 4).
4. Disconnect connector (Figure 2, Item 2) from lens (Figure 2, Item 1).
Figure 3. Bulb.
0207
END OF TASK
CLEANING AND INSPECTION
000207
1. Clean and inspect all mechanical components IAW Mechanical General Maintenance Instructions (WP 0346).
2. Clean and inspect all electrical components IAW Electrical General Maintenance Instructions (WP 0347).
END OF TASK