TM 5-3805-293-23-3
0144
REMOVAL CONTINUED
1. Remove three bolts (Figure 1, Item 6) from cover (Figure 1, Item 5).
2. Remove cover (Figure 1, Item 5) from housing (Figure 1, Item 1).
3. Remove O-ring (Figure 1, Item 4) from cover (Figure 1, Item 5). Discard O-ring.
N OT E
Discard magnetic filter if cracked or damaged.
4. Remove suction screen (Figure 1, Item 2) and magnetic filter (Figure 1, Item 3) from housing (Figure 1, Item 1).
Figure 1. Suction Screen and Magnetic Filter.
0144
END OF TASK
CLEANING AND INSPECTION
000144
1. Clean and inspect all parts IAW Mechanical General Maintenance Instructions (WP 0346).
2. Clean suction screen with firm brush. Allow to air dry.
END OF TASK