TM 5-3805-293-23-3
0142
INSTALLATION CONTINUED
50. Install new O-ring (Figure 73, Item 2) and connect tube (Figure 73, Item 3) to filter housing (Figure 73, Item 1).
51. Install new O-ring (Figure 73, Item 5) and connect tube (Figure 73, Item 3) to fan bypass valve (Figure 73,
Item 4).
Figure 73. Bypass Tube.
0142
52. Reposition wiring harness (Figure 74, Item 3) and install two clamps (Figure 74, Item 5), washers (Figure 74,
Item 4) and bolts (Figure 74, Item 1) on transmission (Figure 74, Item 2).
Figure 74. Transmission ECM Connectors.
0142