Figure 103. Hose Coupling and Pipe Coupling.
Figure 106. Pressure Test Hoses.

Maintenance Manual For Motorized Road Grader Model 120M - 3
Page Navigation
  81    82    83    84    85  86  87    88    89    90    91  
img
.
TM 5-3805-293-23-3
0043
SOLENOID VALVE (AWD PUMP DISPLACEMENT) TEST CONTINUED
00043
3. Position drain pan under machine.
4. Remove test port left reverse plug (Figure 105, Item 1) and O-ring (Figure 105, Item 2) from left AWD pump
(Figure 105, Item 9).
5. Install hose coupling (Figure 105, Item 3) and O-ring (Figure 105, Item 4) in test port left reverse.
6. Remove test port left forward plug (Figure 105, Item 7) and O-ring (Figure 105, Item 8) from left AWD pump
(Figure 105, Item 9).
7. Install hose coupling (Figure 105, Item 5) and O-ring (Figure 105, Item 6) in test port left forward.
Figure 105. Left Reverse and Forward Test Ports.