TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2182-06 Blade Pitch Back-
System Response:
ECM will log diagnostic code.
Above Normal - Continued
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2182-13 Code Active - Proceed to
implement 120M and verify 2182-
Test Step 2.
13 is active.
2182-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2182-03, 2182 05, or 2182-06 Code
Active - Troubleshoot other
2165-03, 2165-05, or 2165-06 are
diagnostic codes first in this work
not active.
package.
2182-13 Code Only Active - Proceed
to step 2.
Blade Pitch Backward Solenoid
2. Calibrate blade Pitch backward
Cannot Be Calibrated - Replace
blade pitch backward solenoid (WP
Moves with Joystick in Hold Posi-
0245).
Proceed to step 3.
Blade Pitch Backward Solenoid
Calibrated - Proceed to step 3.
3. Using MSD (WP 0006), select
2182-13 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2182-13 is active.
beginning.
2182-13 Code Not Active -
Troubleshooting complete.
END OF WORK PACKAGE
0030-64