Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  897    898    899    900    901  902  903    904    905    906    907  
img
TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2182-05 Blade Pitch Back-
System Response:
ward Solenoid Current
ECM will log diagnostic code.
Below Normal
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2182-05 Code Active - Proceed to
implement 120M and verify 2182-
Test Step 2.
05 is active.
2182-05 Code Not Active -
Troubleshooting complete.
Test Step 2. Test for Faulty Blade
Pitch Backward Solenoid.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect front attachment wir-
ing harness connector U-C42
(WP 0009, Figure 234) from blade
pitch backward solenoid (WP
0009, Figure 235) (WP 0180).
3. Connect jumper wire between
front attachment wiring harness
connector U-C42 (WP 0009, Fig-
ure 234) terminal 1 and terminal
2.
2182-06 Code Active - Replace
4. Using MSD (WP 0006), select
blade pitch backward solenoid (WP
implement 120M and check if
0245).
code 2182-06 becomes active.
Proceed to step 5.
2182-05 Code Remains Active -
Proceed to Test Step 3.
5. Using MSD (WP 0006), select
2182-05 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2182-05 is not active.
beginning.
2182-05 Code Not Active -
Troubleshooting complete.
0030-59