TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2181-06 Blade Pitch Forward
Test Step 2. Test for Faulty Blade
Pitch Forward Solenoid.
Normal - Continued
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect front attachment wir-
ing harness connector U-C41
(WP 0009, Figure 232) from blade
pitch forward solenoid (WP 0009,
Figure 233) (WP 0180).
3. Using MSD (WP 0006), select
2181-05 Code Active - Replace
implement 120M and check if
blade pitch forward solenoid (WP
code 2181-05 becomes active.
0245).
Proceed to step 4.
2181-06 Code Remains Active -
Proceed to Test Step 3.
4. Using MSD (WP 0006), select
2181-06 Code Active - Repeat
implement 120M ECM and verify
troubleshooting code from the
2181-06 is not active.
beginning.
2181-06 Code Not Active -
Troubleshooting complete.
Test Step 3. Test for Shorted Cab
Lower Wiring Harness.
1. Turn ignition switch and battery
disconnect switch to the OFF
position.
2. Disconnect cab lower wiring har-
ness connector P-C41 (WP 0009,
Figure 68) from implement 1 ECM
J1 (WP 0009, Figure 69) (WP
0268).
sure for continuity between cab
lower wiring harness connector P-
ECM (WP 0268).
C41 (WP 0009, Figure 68) termi-
Connect front attachment wiring
nal 48 and terminal 50. There
harness connector U-C41 (WP 0009,
should be no continuity.
Figure 232) to blade pitch forward
0180).
Proceed to step 4.
0030-54