TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2170-13 Circle Sideshift
System Response:
ECM will log diagnostic code.
bration
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2170-13 Code Active - Proceed to
implement control #2 and verify
Test Step 2.
2170-13 is active.
2170-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2170-03, 2170 05, or 2170-06 Code
Active - Troubleshoot other
2170-03, 2170-05, or 2170-06 are
diagnostic codes first in this work
not active.
package.
2170-13 Code Only Active - Proceed
to step 2.
Circle Sideshift Right Solenoid
2. Calibrate circle sideshift right
Cannot Be Calibrated - Replace
circle sideshift right solenoid (WP
Moves with Joystick in Hold Posi-
0245).
Proceed to step 3.
Circle Sideshift Right Solenoid
Calibrated - Proceed to step 3.
3. Using MSD (WP 0006), select
2170-13 Code Active - Repeat
implement control #2 ECM and
troubleshooting code from the
verify 2170-13 is active.
beginning.
2170-13 Code Not Active -
Troubleshooting complete.
0030-17