TM 5-3805-293-23-2
0030
Table 1. Implement Code (2169-03 to 2182-13) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
2169-13 Circle Sideshift Left
System Response:
ECM will log diagnostic code.
N OT E
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a con-
nection is found, correct the problem and verify that this diagnostic code
is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Test Step 1. Test for Active Code.
1. Using MSD (WP 0006), select
2169-13 Code Active - Proceed to
implement control #2 and verify
Test Step 2.
2169-13 is active.
2169-13 Code Not Active -
Troubleshooting complete.
Test Step 2. Verify Other Diagnostic
Codes are Not Active.
1. Using MSD (WP 0006) verify
2169-03, 2169 05, or 2169-06 Code
2165-03, 2165-05, or 2165-06 are
Active - Troubleshoot other
not active.
diagnostic codes first in this work
package.
2169-13 Code Only Active - Proceed
to step 2.
2. Calibrate circle sideshift left sole-
Circle Sideshift Left Solenoid
noid, refer to Any Implement
Cannot Be Calibrated - Replace
Moves with Joystick in Hold Posi-
0245).
Proceed to step 3.
Circle Sideshift Left Solenoid
Calibrated - Proceed to step 3.
2169-03 Code Active - Repeat
3. Using MSD (WP 0006), select
troubleshooting code from the
implement control #2 ECM and
beginning.
verify 2169-03 is not active.
2169-03 Code Not Active -
Troubleshooting complete.
0030-9