Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.

Maintenance Manual For Motorized Road Grader Model 120M - 2
Page Navigation
  620    621    622    623    624  625  626    627    628    629    630  
img
TM 5-3805-293-23-2
0027
Table 1. Implement Code (0615-02 TO 2113-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
1471-14 Steering Control
2. Using the MSD (WP 0006), select  1471-14 Code Active - Repeat
Position Sensor #1 Special
Implement 120M and verify 1471- troubleshooting code from the
Instruction - Continued
14 is not active.
beginning.
1471-14 Code Not Active -
Troubleshooting complete.
Test Step 5. Test for Open Cab
Upper Wiring Harness to Imple-
ment ECM.
1. Remove jumper wire between P-
C51 terminal 2 and terminal 4
(WP 0009, Figure 118).
2. Connect jumper wire between P-
C51 terminal 2 and terminal 8
(WP 0009, Figure 118).
0027-70