  476    477    478    479    480  481  482    483    484    485    486  
img
TM 5-3805-293-23-2
0026
Table 1. Implement Code (0041-03 to 0600-04) Troubleshooting Procedures - Continued.
CDI FMI CODE
TEST OR INSPECTION
CORRECTIVE ACTION
0168-01 Electrical System
4. Using digital multimeter, test for
Voltage Less Than 18 Volts -
Voltage Low (Implement 2) -
voltage between harness connec-
Replace rear chassis wiring harness
Continued
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 31 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 5.
5. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 38 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 6.
6. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 39 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 7.
7. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 46 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to step 8.
8. Using digital multimeter, test for
Voltage Less Than 18 Volts -
voltage between harness connec-
Replace rear chassis wiring harness
tor FA-C20 (WP 0009, Figure 113)
(WP 0188).
terminal 47 and machine ground.
Proceed to step 9.
Voltage should be between 18 to 26
Voltage Between 18 to 26 Volts -
volts.
Proceed to Test Step 3.
9. Using the MSD (WP 0006), select
0168-01 Code Remains Active -
Implement Control #2 120M and
Proceed to Test 2.
verify 0168-01 is not active.
0168-00 Code Not Active -
Troubleshooting complete.
0026-20