TM 5-3805-293-23-2
0025
Table 1. Implement Troubleshooting Procedures - Continued.
MALFUNCTION
TEST OR INSPECTION
CORRECTIVE ACTION
5. When Implement is
1. Inspect hydraulic oil for correct
Oil Level OK - Proceed to step 2.
First Activated, Imple-
level and type (LO 5-3805-293-
Oil Level Low - Drain and refill
ment Surges
13).
hydraulic tank (LO 5-3805-293-13)
and perform oil configuration (WP
0217). Proceed to step 4.
Oil Incorrect for Operating Condi-
tions - Drain and refill hydraulic tank
(WP 0217) and replace hydraulic fil-
ter (WP 0208). Perform oil configura-
tion (WP 0217). Proceed to step 4.
2. Perform Margin Pressure Adjust-
Pressure Cannot Be Adjusted or
ment (WP 0044).
Remains Low - Replace implement
steering pump control valve (WP
0121). Proceed to step 4.
Pressure OK - Proceed to step 3.
3. Operate affected implement.
Implement Surges - Replace
Implement and Steering Pump (WP
0120). Proceed to step 4.
Implement OK - Proceed to step 4.
4. Start and run machine (TM 5-
3805-293-10) to verify malfunc-
tion has been corrected.
END OF WORK PACKAGE