TM 5-3805-293-23-1
0011
Table 2. Engine Troubleshooting with Codes for the 120M Motor Grader - Continued.
CDI FMI CODE
ERROR/EVENT
CORRECTIVE ACTION
1797-03 Fuel Rail Pressure
Test Step 1. Test Signal Circuit.
Sensor Voltage Above Nor-
N OT E
mal - Continued
Always inspect the harness connectorsthat are involved in the circuit.
Poor connections can often be the cause of a problem in an electrical
circuit. Verify that all connections in the circuit are clean and secure,
and that all connections are in good condition. If a problem with a
connection is found, correct the problem and verify that this diagnostic
code is active before performing this procedure.
Perform open or short circuit test ateach harness connection to identify
correct harness to replace.
Perform this test only if condition is active.
Diagnostic Code 1797-03 Active -
Engine ECM C6.6 120M and ver-
Proceed to step 2.
ify 1797-03 is active.
2. Turn ignition switch to the OFF
position.
3. Disconnect the fuel rail pressure
25) harness connector.
4. Install a jumper wire between har-
Figure 25) terminal 3 and ground.
5. Turn ignition switch to the ON
position.
N OT E
Wait at least 30 seconds in order for diagnostic codes to become active.
1797-03 Remains Active - Proceed
to step 11.
Engine ECM C6.6 120M, and
check if diagnostic code 1797-04
1797-04 Becomes Active - ECM and
is active.
signal circuit test OK proceed to
step 7.
7. Turn the ignition switch and
battery disconnect switch to the
OFF position.
8. Remove jumper wire from
harness connector EA-C6 (WP
0009, Figure 25) terminal 3 and
ground.
9. Install a jumper wire between
harness connector EA-C6 (WP
0009, Figure 25) terminal 2 and
terminal 3.
0011-167
Change 1