HOW TO USE ELECTRONIC TECHNICIAN (ET)
Figure 2. Diagnostic Connector.

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  57    58    59    60    61  62  63    64    65    66    67  
img
.
TM 5-3805-293-23-1
0006
CONNECT MSD
1. Turn ignition switch and battery disconnect switch to the OFF position (TM 5-3805-293-10).
2. Connect cable (Figure 1, Item 9) to COMPUTER end of communication adapter (Figure 1, Item 2) and to USB
port (Figure 1, Item 11) of MSD (Figure 1, Item 1).
3. If power supply is available, connect power supply cable (Figure 1, Item 8) to power supply port (Figure 1,
Item 10) on MSD (Figure 1, Item 1).
4. If power supply is available, connect power supply cable (Figure 1, Item 5) to power supply (Figure 1, Item 6)
and power source.
Figure 1. Electronic Technician Components.