Table 1. Detailed FMI Explanation - Continued.
HOW TO USE ELECTRONIC TECHNICIAN (ET)

Maintenance Manual For Motorized Road Grader Model 120M - 1
Page Navigation
  55    56    57    58    59  60  61    62    63    64    65  
img
TM 5-3805-293-23-1
0005
FAILURE MODE IDENTIFIERS (FMIS) CONTINUED
Table 1. Detailed FMI Explanation - Continued.
FMI
DESCRIPTION
EXPLANATION
11
Failure Mode Not
Control identifies more than one FMI as being responsible for a single failure.
Identifiable.
Some possible causes of an FMI 11 diagnostic code are:
There is a mechanical failure.
There is damage tomultiple circuits.
12
Bad Equipment or
Electronic control sends a signal and electronic control expects a response.
Component.
Control receives no response or response is incorrect. Some possible causes
of an FMI 12 diagnostic code are:
There is a failure of electronic control.
There is a failure on data link.
There are one or more controls with mismatched software.
13
Out of Calibration.
An electrical signal is not within limits for a specific mechanical condition.
Some possible causes of an FMI 13 diagnostic code are:
Calibration is required.
Data are out of range.
14
This code is not active.
15
This code is not active.
16
Parameter Not
Control does not support requested parameter.
Available.
17
Module Not
Control does not respond to request for data.
Responding.
18
Sensor Supply
Sensor power supply in control has failed.
Failure.
19
Condition Not Met.
Conditions defined by software were not met.
20
This code is not active.
END OF TASK